Print Report | Back to Test Summary

Testing Report for 2021-05-05-12-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215405 DEA: 032G1604 EFIS: 0320000235 QA Service Level: 1
DIST-CO-RTE-PM: 03-YOL-45-0.6/12.9
Work Description: COLD PLANE AC PAVEMENT AND REPLACE WITH HOT MIX ASPHALT.
Location Description: YOLO COUNTY NEAR KNIGHTS LANDING FROM SYCAMORE SLOUGH BRIDGE TO YOLO COUNTY LINE ROAD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Luis Pompa Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-05-05-12
TL Number from the TL Form: c783775
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 05/05/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/07/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: PG64-16
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Hollwood

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number: 2
Sublot number: 10
Tank number:
Time of sample:
HMA Supplier: Teichert Hollwood
Asphalt Binder Supplier: Marathon Petroleum Co. LP - Elk Grove CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-05-05-12-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 05/21/2021
Date Tested: 05/10/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: as per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Minimum test bath temperature at 240 s -6.0 C
Maximum test bath temperature at 240 s -6.0 C
Time of test load application no data HH:MM:SS
File name of test data no data
Time beam in bath no data
Time test started no data HH:MM:SS
Flags issued by software during test no data
Correlation coefficient (R²) 0
Regression coefficient a no data
Regression coefficient b no data
Regression coefficient c no data
Load at time 0.0 0.0 mN
Deflection at time 0.0 s 0.000 µm
Load at time 0.5 s 0.0 mN
Deflection at time 0.5 s 0.000 µm
Load at 60.0 s 1033.0 mN
Beam deflection 60.0 s 0.860 µm
Measured Stiffness Modulus 60.0 s 96.800 mPa
Estimated Stiffness Modulus 60.0 s 96.600 mPa
Difference between stiffness moduli 60.0 s -0.21 %
Estimated m-value 60.0 s 0.401