Contract # 033F0904 Cty SAC Rte 5 PM Var Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Mohssen Ghassemi |
Date Reported: |
06/01/2021 |
|
Address: |
TL Number: |
114319 |
||
City: |
||||
Project Name: REPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES. |
||||
Prime Contractor: Myers & Sons Construction |
||||
Sample Taken Date: |
05/03/2021 |
Mix Design: |
1615759 |
|
Contractor: Unknown |
Location: SACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE |
|||
Structure unique identifier: |
||||
Structure name: Pile 3 Abut 22R |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.97 | 27.99 | 125988 | 4501.0 | 1 |
2 | 5.98 | 28.09 | 132152 | 4705.0 | 1 |
DIME Test ID: 2021-05-03-8-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4600
Age of specimen: 7 days
Certified By: Mike Mullins
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.99 | 28.18 | 158831 | 5636.0 | 1 |
2 | 5.99 | 28.18 | 151937 | 5392.0 | 1 |
DIME Test ID: 2021-05-03-8-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5510
Age of specimen: 29 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing