Print Report | Back to Sample Detail

Sample Record for 2021-04-28-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212571 DEA: 051F79A4 EFIS: 0514000061 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-55.9/R56.2
Work Description: Nojoqui Creek Bridge (51-0018 L/R) widening and rail replacement.
Location Description: IN SANTA BARBARA COUNTY NEAR BUELLTON AT NOJOQUI CREEK BRIDGE (BR #51-0018 L/R)
Contractor Name: SOUZA CONSTRUCTION
Contractor Address: 4027 Santa Fe Road, San Luis Obispo, CA 93403
Resident Engineer: David Cooper Structure Rep.: Sal Heredia

Sample Information

DIME Sample ID: 2021-04-28-13
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 04/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 05/03/2021
The quantity of what the sample constitutes: 1
A brief description of the sample: bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 19974-1
Material/Compound/Elastomer ID: na
Samples Representing: 11
Description (size): 1.72"x12"x12"
Comments:
Description (Number of Shims): 3
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na

Test Results

Test 1 of 4

DIME Test ID: 2021-04-28-13-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 05/20/2021
Date Tested: 05/04/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 51
Reading #2 51
Reading #3 51
Reading #4 50
Reading #5 52
Mean 51

Test 2 of 4

DIME Test ID: 2021-04-28-13-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 05/20/2021
Date Tested: 05/07/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.075
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2881.16 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.082
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2737.19 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.085
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2637.89 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2737.2 lbf/in^2

Test 3 of 4

DIME Test ID: 2021-04-28-13-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 05/20/2021
Date Tested: 05/07/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.086
Sample 1 Tear Strength 226.9
Sample 2 Median Thickness 0.079
Sample 2 Tear Strength 233.9
Sample 3 Median Thickness 0.083
Sample 3 Tear Strength 227.5
Median of the Tear Strength Values 227.5 lb/in

Test 4 of 4

DIME Test ID: 2021-04-28-13-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 05/10/2021
Date Tested: 05/10/2021
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass