Print Report | Back to Sample Detail

Sample Record for 2021-04-23-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-8.2/8.7
Work Description: Panther Creek & Hunter Creek Bridges
Location Description: DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Contractor Name: Golden State Bridge, Inc
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Ryan Dunne Structure Rep.: Brian Cinkutis

Sample Information

DIME Sample ID: 2021-04-23-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Acceptance
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 04/23/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/28/2021
The quantity of what the sample constitutes: 1 Plate
A brief description of the sample: 1" ASTM A709 Gr50T1/T2 Plate
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Thompson Metal Fab

Material Information

Heat Number(s): 0606338
Material Specification: A709
Grade: 50T1/T2
Thickness: 1
Shape: Plate
Metal Foundry Manufacturer (Mill): Nucor
Plate Dimension: Unknown

Test Results

Test 1 of 3

DIME Test ID: 2021-04-23-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/06/2021
Date Tested: 05/05/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
06063380.5010.19714603268725323.7bewing
06063380.5010.19714607618797125.7bewing
UTM 67kip
Temperature 72 F

Test 2 of 3

DIME Test ID: 2021-04-23-2-2
Test Method: ASTM E415-17: Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry
Verified Date: 05/06/2021
Date Tested: 05/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Content, carbon 0.164 %
Content, Si 0.184 %
Content, Mn 1.38 %
Content, P 0.0099 %
Content, S 0.0018 %
Content, Cr 0.081 %
Content, Mo 0.028 %
Content, Al 0.029 %
Content, Co 0.013 %
Content, Copper 0.278 %
Content, Nb 0.0014 %
Content, Ti 0.0019 %
Content, V 0.047 %
Content, Lead 0.0080 %
Content, Boron 0.0005 %
Content, Fe 97.5 %
Content, Ni 0.140 %

Test 3 of 3

DIME Test ID: 2021-04-23-2-3
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 05/06/2021
Date Tested: 05/06/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature Required 40 oF
Minimum Energy Required 25 ftlb
Test Temperature 1 40 oF
Impact Energy 1 23.6 ftlb
Impact Energy 2 33.3 ftlb
Impact Energy 3 19.3 ftlb
Average Impact Energy 25 ftlb
Striker Radius 8
Value Exceeds The Machine Capacity? No