Print Report | Back to Test Summary

Testing Report for 2021-04-27-10-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 11424904
EFIS: 1116000094
Project ID: 214858
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5,8,15,52,54-Var
Work Description: Install roadside signs.
Location Description: 11-SD-5, 8, 15, 52, 54, etc.-Var.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Genaro Genel
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-27-10
TL Number from the TL Form: na
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 4/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/27/2021
The quantity of what the sample constitutes: 146
A brief description of the sample: F1554-55 Anchor Bolt
From where was the sample collected: Fabricator
Laboratory sample identification: na
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): na
Heat Number(s): 1201022732
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: F1554-55 S1
Bolt Length(s): 4'-2"
Nut Specification: na
Washer Specification: na
Finish: HGD/Plain
Diameter/Size: 2"
Bolt Mfg. Lot Number: na
Rocap Test Requirement(s): na
Lubricant Requirements(s): Plain

Test Information

DIME Test ID: 2021-04-27-10-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 5/6/2021
Verified Date: 5/20/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
1 1201022732 0.501 0.197 62977 90071 25.6 bewing
UTM: 67kip
Temperature: 72 f