Print Report | Back to Test Summary

Testing Report for 2021-04-12-51-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: ASCP
EFIS: ASCP
Project ID: 44444
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-12-51
TL Number from the TL Form:
Sample Submitted By Organization: San Joaquin Refinery - Bakersfield
Sample Organization Contact: (661) 327-8248
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 4/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/12/2021
The quantity of what the sample constitutes: 1 of 2 cans
A brief description of the sample: Neat Asphalt Binder
From where was the sample collected: Manufacturer
Laboratory sample identification: PG7010-210412
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refinery

Material Information

Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number: 9001
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:

Test Information

DIME Test ID: 2021-04-12-51-1
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Date Tested: 4/12/2021
Verified Date: 5/3/2021
Submitted By Organization: San Joaquin Refinery - Bakersfield
Organization Address: 3500 Shell St,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email:
Organization Phone: (661) 327-8248
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Observed Flash Point: 303 C
Ambient Barometric Pressure: 754 mmHg
Cleveland Open-Cup Flash Point in Celsius: 304 C