Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-04-05-24
TL Number from the TL Form:
Sample Submitted By Organization: Valero-NuStar PAT - Pittsburg
Sample Organization Contact: (707) 745-7089
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 04/05/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/07/2021
The quantity of what the sample constitutes: 1 of 2 split sample
A brief description of the sample: Asphalt Binder PG 64-16
From where was the sample collected: Manufacturer
Laboratory sample identification: 6416-040521
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Pittsburg
Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number: 150
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero-NuStar PAT - Pittsburg CA
Multigrade: Yes
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-04-05-24-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Average mass change
|
-0.424 percent
|
DIME Test ID: 2021-04-05-24-2
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 04/30/2021
Date Tested: 04/09/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test: Note: Stiffness should be to 3 significant figures not 3 decimal points
Test Result Compliance:
Additional Comments When Verified:
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
0.0 mN
|
Beam deflection 60.0 s
|
0.000 µm
|
Measured Stiffness Modulus 60.0 s
|
56.450 mPa
|
Estimated Stiffness Modulus 60.0 s
|
56.350 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.415
|
DIME Test ID: 2021-04-05-24-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test: Note: DSR New method is T315-20, you only have 315-12, 315-16 available. Why require phase angle result & not G*/sinDelta.
Test Result Compliance:
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
85.6 degree
|
Dynamic Shear, G*/sin(δ)
|
1.52 kPa
|
DIME Test ID: 2021-04-05-24-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Phase Angle (δ) (for the 10 cycles)
|
81.0 degree
|
Dynamic Shear, G*/sin(δ)
|
3.93 kPa
|
DIME Test ID: 2021-04-05-24-5
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/30/2021
Date Tested: 04/09/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Phase Angle (δ) (for the 10 cycles)
|
50.4 degree
|
(G*) x sin(δ)=
|
2060 kPa
|
DIME Test ID: 2021-04-05-24-6
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Verified Date: 05/26/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test: Note: newer AASHTO T316-19 available. Torque error if input decimal point, actual torque 16.6.
Test Result Compliance:
Additional Comments When Verified:
Is viscosity reading in cP/Pa-s?
|
Pa-s
|
Time of test
|
05:05 HH:MM
|
Test Temperature
|
135 C
|
Speed
|
20 rpm
|
Spindle size
|
S21 in
|
Torque
|
17 %
|
Viscosity reading #1 (A)
|
0.418 Pa-s
|
Viscosity reading #2 (B)
|
0.414 Pa-s
|
Viscosity reading #3 (C)
|
0.417 Pa-s
|
Average viscosity
|
0.416 Pa-s
|
DIME Test ID: 2021-04-05-24-7
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg)
|
Celsius and mmHg
|
Observed Flash Point
|
312 C
|
Ambient Barometric Pressure
|
752 mmHg
|
Cleveland Open-Cup Flash Point in Celsius
|
312 C
|
DIME Test ID: 2021-04-05-24-8
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 04/30/2021
Date Tested: 04/07/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test: 150+, Note: Newer AASHTO test is T51-09(18)
Test Result Compliance:
Additional Comments When Verified:
Is a normal test obtainable?
|
Yes
|
Number of replicates tested
|
Three
|
Ductility of test #1 (D1)
|
150 cm
|
Ductility of test #2 (D2)
|
150 cm
|
Ductility of test #3 (D3)
|
150 cm
|
Ductility of sample
|
150 cm
|
DIME Test ID: 2021-04-05-24-9
Test Method: AASHTO R28-16: Accelerated Aging of Asphalt Binder Using a Pressurized Aging Vessel (PAV)
Verified Date: 04/30/2021
Date Tested: 04/08/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Road,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email: patrick.sendegeya@valero.com
Organization Phone: (707) 745-7214
General Comments for this Test: APART PAV does not record Min/Max temp, Note Sample ID does not allow - dashes. What ID do you want?
Test Result Compliance:
Additional Comments When Verified:
Sample identification
|
6416040521
|
Aging Test Temperature, nearest 0.5 C
|
100.0 C
|
Minimum aging temperature recorded
|
100.0 C
|
Maximum aging temperature recorded
|
100.0 C
|
Total time during aging that temperature was outside the specified range
|
1 minutes
|
Total aging time (hour)
|
20 hours
|
Total aging time (minute)
|
0 minutes
|
The heating temperature
|
100 C
|