Print Report | Back to Test Summary

Testing Report for 2021-04-05-24-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: ASCP
EFIS: ASCP
Project ID: 44444
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-04-05-24
TL Number from the TL Form:
Sample Submitted By Organization: Valero-NuStar PAT - Pittsburg
Sample Organization Contact: (707) 745-7089
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 4/5/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/7/2021
The quantity of what the sample constitutes: 1 of 2 split sample
A brief description of the sample: Asphalt Binder PG 64-16
From where was the sample collected: Manufacturer
Laboratory sample identification: 6416-040521
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero Pittsburg

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number: 150
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: Valero-NuStar PAT - Pittsburg CA
Multigrade: Yes
Multigrade Type:

Test Information

DIME Test ID: 2021-04-05-24-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 4/7/2021
Verified Date: 4/30/2021
Submitted By Organization: Valero-NuStar PAT - Pittsburg
Organization Address: 1100 Willow Pass Rd,
Organization City: Pittsburg
Organization State: CA
Organization Zipcode: 94565
Organization Email:
Organization Phone: (707) 745-7089
General Comments for this Test: Note: DSR New method is T315-20, you only have 315-12, 315-16 available. Why require phase angle result & not G*/sinDelta.
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Phase: Original binder
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 85.6 degree
Dynamic Shear, G*/sin(δ): 1.52 kPa