Print Report | Back to Test Summary

Testing Report for 2021-04-02-12-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 010F3104
EFIS: 0115000108
Project ID: 214873
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-39.8
Work Description: REMOVE REINFORCED CONCRETE BOX CULVERT AND CONSTRUCT BRIDGE.
Location Description: DEL NORTE COUNTY NEAR SMITH RIVER AT DOMINIE CREEK
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Karen Sanders
Structure Rep.: Brian Cinkutis

Sample Information

DIME Sample ID: 2021-04-02-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 4/2/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/6/2021
The quantity of what the sample constitutes: 21 Cylinders
A brief description of the sample: 3x6 UHPC Cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Stage 2 UHPC Keyway between Box Girder G and H per Plan
The fabricator/manufacturer/facility name: McCullough Construction Inc

Material Information

The concrete mix design number: JS1000
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Unknown
Where the material sample would have been placed if not sampled:
From Lot No.: RXX J1518 A1
Bag Lot No.:

Test Information

DIME Test ID: 2021-04-02-12-4
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 4/30/2021
Verified Date: 4/30/2021
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 5
Test performed: With no density determined
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 3.01 in
Average diameter of cylinder 2: 2.99 in
Average diameter of cylinder 3: 3.01 in
Average diameter of cylinder 4: 2.99 in
Average diameter of cylinder 5: 2.99 in
Cross sectional area of cylinder 1: 7.12 in^2
Cross sectional area of cylinder 2: 7.02 in^2
Cross sectional area of cylinder 3: 7.12 in^2
Cross sectional area of cylinder 4: 7.02 in^2
Cross sectional area of cylinder 5: 7.02 in^2
Compressive strength (to nearest 10 psi): 24050 psi
Maximum load on cylinder 1: 164957 lb
Maximum load on cylinder 2: 176513 lb
Maximum load on cylinder 3: 171746 lb
Maximum load on cylinder 4: 171019 lb
Maximum load on cylinder 5: 164765 lb
Compressive strength of cylinder 1: 23168.1 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 25144.3 psi
Compressive strength of cylinder 3: 24121.6 psi
Compressive strength of cylinder 4: 24361.7 psi
Compressive strength of cylinder 5: 23470.8 psi
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Type of fracture pattern of cylinder 4: 1
Type of fracture pattern of cylinder 5: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Correction factor for cylinder 4: 1
Correction factor for cylinder 5: 1
Age of specimen: 28 days
Age of specimen in hours: no data