Print Report | Back to Test Summary

Testing Report for 2021-03-04-16-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: AML-CEM
EFIS: AML-CEM
Project ID: 8801
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-03-04-16
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 3/4/2021
Date that the sample was received by the laboratory/organization performing the testing: 3/4/2021
The quantity of what the sample constitutes: 1 box
A brief description of the sample: Blended cement
From where was the sample collected: Supplier
Laboratory sample identification: CM218088
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL

Material Information

Brand: CCRL
Mill: Blended Cement 88
Type of Cementitious Material: Blended Cement

Test Information

DIME Test ID: 2021-03-04-16-4
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Date Tested: 4/16/2021
Verified Date: 4/16/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test @ 15:50
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Will control cubes be used per ASTM C311?: no
Age of specimen: 31 days
The amount of flow : 111.00 %
The amount of water used : 44.6 %
Compressive strength of 1st specimen : 6562 psi
Compressive strength of 2nd specimen: no data
Compressive strength of 3rd specimen : no data
Average Compressive strength (to nearest 10 psi): no data