Print Report | Back to Test Summary

Testing Report for 2020-11-19-10-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030H10U4
EFIS: 0317000246
Project ID: 213411
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-5-9.7/24.9
Work Description:
Location Description: Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Girmay Beyene
Structure Rep.: Luis Guzman

Sample Information

DIME Sample ID: 2020-11-19-10
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT D03 - North Region Materials Lab
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/19/2020
Date that the sample was received by the laboratory/organization performing the testing: 2/8/2021
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 3/4" HMA - A w/RAP (Long Life, Int)
From where was the sample collected: Manufacturer
Laboratory sample identification: JMF21-006
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Company -- Bradshaw Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:

Test Information

DIME Test ID: 2020-11-19-10-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Date Tested: 4/2/2021
Verified Date: 4/14/2021
Submitted By Organization: CT D03 - North Region Materials Lab
Organization Address: 5330 Arboga Rd,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF21-006.
Test Result Compliance: complies
Additional Comments When Verified : JMF21-008

Submitted Test Results

Percent Air Voids: 2.6 %
Percent Air Voids 2: 3
Percent Air Voids 3: 2.6
Percent Air Voids Average: 2.7