Print Report | Back to Test Summary

Testing Report for 2021-04-01-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 010B0904
EFIS: 0100020444
Project ID: 214579
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-8.2/8.7
Work Description: BRIDGE REPLACEMENT
Location Description: DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Ryan Dunne
Structure Rep.: Bryan Keene

Sample Information

DIME Sample ID: 2021-04-01-1
TL Number from the TL Form:
Sample Submitted By Organization: Caltrans Vallejo Field Laboratory
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 4/1/2021
Date that the sample was received by the laboratory/organization performing the testing: 4/6/2021
The quantity of what the sample constitutes: 100
A brief description of the sample: Dayton Dowel Bar couplers
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: Panther Creek
The fabricator/manufacturer/facility name: PJ Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Dayton Superior
Intermediate Assembler or Fabricator: PJ Rebar
Rebar Size: #10
Coupler Model: Dayton D101
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 1291792, 1291798
Rebar Heat Number(s): SE17105421
Rebar Size 2 : 10

Test Information

DIME Test ID: 2021-04-01-1-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Date Tested: 4/6/2021
Verified Date: 4/6/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples Tested: 1
Sample Number of Cycles Size Mfg. Lot Number(s) Slip (inch) Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
1 No. 10/32mm 1 -0.0044 1.27 118541 93340 OK Necking fsaylor
UTM: 2000kip
Temperature: 72.00 f
Halo ID: Small