Print Report | Back to Test Summary

Testing Report for 2021-03-26-11-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081C38U4
EFIS: 0817000196
Project ID: 213707
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-6.7/R25.1
Work Description: Remove concrete pavement and base, and place HMA and JPCP
Location Description: ROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Elvira Lenart
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-03-26-11
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 3/26/2021
Date that the sample was received by the laboratory/organization performing the testing: 3/29/2021
The quantity of what the sample constitutes: 6 Bags of Combined, 3 Bags of RAP
A brief description of the sample: PSUE 3/8" HMA-A-SP R15 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0175A-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: California Commercial Asphalt - Lake Elsinore

Material Information

Source Identification (SMARA or name of Pit): 91-33-0098, 91-33-0011
The fabricator's/manufacturer's product name for the sample: 3/8 HMA-A-SP R15
The fabricator/manufacturer designation for the sample:
The plant number: 53891193
A detailed description of where the material sample was collected: Belt Cut at California Commercial Asphalt Lake Elsinore Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-03-26-11-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Date Tested: 4/5/2021
Verified Date: 4/9/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %