Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215147 DEA: 060X0404 EFIS: 0618000013
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-65,190-0.0/R15.1,8.0/26.5
Work Description: INSTALL RUMBLE STRIPS.
Location Description: TULARE COUNTY NEAR PORTERVILLE ON ROUTE 65 FROM KERN COUNTY LINE TO 0.5 MILE SOUTH OF AVENUE 124 AND ON ROUTE 190 FROM ROAD 180 TO PLEASANT OAK DRIVE
Contractor Name: Global Road Sealing Inc
Contractor Address: 10832 Dorothy Ave, Garden Grove, CA, 92843
Resident Engineer: Jake Garcia Structure Rep.: Unknown
DIME Sample ID: 2021-03-25-12
TL Number from the TL Form: C056402
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 03/25/2021
Date that the sample was received by the laboratory/organization performing the testing: 04/05/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Asphalt Binder
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Porterville Asphalt
Performance Grade: PG 64-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier: Porterville Asphalt
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2021-03-25-12-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 04/07/2021
Date Tested: 04/06/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 standard specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
166.869 grams
|
Mass of empty container #2
|
173.001 grams
|
Mass of container #1 before test (m1i)
|
202.413 grams
|
Mass of container #2 before test (m2i)
|
208.369 grams
|
Mass of container #1 after test (m1f)
|
202.141 grams
|
Mass of container #2 after test (m2f)
|
208.036 grams
|
Average mass change
|
-0.853 percent
|
DIME Test ID: 2021-03-25-12-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/07/2021
Date Tested: 04/06/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Std Specs ORIG
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.158 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
89.5 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.320 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.32 kPa
|
DIME Test ID: 2021-03-25-12-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/07/2021
Date Tested: 04/06/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Std Secs RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.247 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
88.9 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
2.473 kPa
|
Test Temperature (Specimen 1)
|
64.0 C
|
Dynamic Shear, G*/sin(δ)
|
2.47 kPa
|
DIME Test ID: 2021-03-25-12-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 04/07/2021
Date Tested: 04/07/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Std. Specs. PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Test Gap
|
2 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
1.00 %
|
Stress Amplitude
|
41.393 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
67.0 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
4139.332 kPa
|
Test Temperature (Specimen 1)
|
31.0 C
|
(G*) x sin(δ)=
|
3810 kPa
|
DIME Test ID: 2021-03-25-12-5
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 04/07/2021
Date Tested: 04/07/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 standard specs
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s
|
0.0 C
|
Maximum test bath temperature at 240 s
|
0.0 C
|
Time of test load application
|
no data HH:MM:SS
|
File name of test data
|
no data
|
Time beam in bath
|
no data
|
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
0.0 mN
|
Beam deflection 60.0 s
|
0.000 µm
|
Measured Stiffness Modulus 60.0 s
|
143.000 mPa
|
Estimated Stiffness Modulus 60.0 s
|
143.000 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.482
|