Testing Report for 2021-02-10-5-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080C2514
EFIS: 0816000076
Project ID: 212112
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2021-02-10-5
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 2/10/2021
Date that the sample was received by the laboratory/organization performing the testing: 2/11/2021
The quantity of what the sample constitutes: 2 cylinders
A brief description of the sample: Concerte Cylinder
From where was the sample collected: Job Site
Laboratory sample identification: 1015-210
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1610974
The truck number from where the sample was collected: 70474
The batch plant ticket number from where the sample was collected: 29469056
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: RW 1028 footing, Load 8
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2021-02-10-5-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 3/10/2021
Capped in accordance with: ASTM C617/CTM521
Verified Date: 4/2/2021
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.56 in^2
Capped in accordance with?: ASTM C617/CTM521
Compressive strength (to nearest 10 psi): 5950 psi
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.03 in
Compressive strength of cylinder 1: 5789.9 psi
Compressive strength of cylinder 2: 6110.8 psi
Maximum load on cylinder 1: 165360 lb
Maximum load on cylinder 2: 174525 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days