Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212085 DEA: 07296604 EFIS: 0713000057
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-14.0/19.0
Work Description: PAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK)
Location Description: IN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE
Contractor Name: CL Industrial Coating Inc.
Contractor Address: 11650 Western Ave., Stanton, CA 90680
Resident Engineer: Susana Facio Structure Rep.: Nabil Shmara
DIME Sample ID: 2021-02-19-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/19/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/19/2021
The quantity of what the sample constitutes: 2000
A brief description of the sample: ASTM F436 Bevel Washer
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Page Industrial
Rocap Number(s):
Heat Number(s): JL9129
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): 317906
Bolt Specification: n/a
Bolt Length(s): n/a
Nut Specification: n/a
Washer Specification: ASTM F436
Finish: Hot Dipped Galvanized
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: n/a
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2021-02-19-10-1
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317906
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
W
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.35 mils
|
DIME Test ID: 2021-02-19-10-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317906
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
W
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.05 mils
|
DIME Test ID: 2021-02-19-10-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317906
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
W
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
6.19 mils
|
DIME Test ID: 2021-02-19-10-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317906
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
W
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.41 mils
|
DIME Test ID: 2021-02-19-10-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/16/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
317906
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
W
|
Size
|
.75 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.2 mils
|