Testing Report for 2021-02-17-12-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: ASCP
EFIS: ASCP
Project ID: 44444
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-02-17-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Preliminary
Type of Material: Asphalt Binder
Sample Taken Date: 2/17/2021
Date that the sample was received by the laboratory/organization performing the testing: 3/4/2021
The quantity of what the sample constitutes: 1 of 3 cans
A brief description of the sample: Asphalt Binder
From where was the sample collected: Manufacturer
Laboratory sample identification: 6428M-021721
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Valero NuStar PAT

Material Information

Performance Grade: PG 64-28 M
Modified: Yes
Lot number:
Sublot number:
Tank number: TK 5003
Time of sample:
HMA Supplier:
Asphalt Binder Supplier: Valero-NuStar PAT - Pittsburg CA
Multigrade:
Multigrade Type:

Test Information

DIME Test ID: 2021-02-17-12-6
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Date Tested: 3/12/2021
Verified Date: 3/12/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Minimum test bath temperature at 240 s: -18.0 C
Maximum test bath temperature at 240 s: -18.0 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): no data
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 126.000 mPa
Estimated Stiffness Modulus 60.0 s: 126.000 mPa
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.345