Sample Record for 2021-03-03-9
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209520 DEA: 06470904 EFIS: 0600000973 COOP: 061529
QA Service Level: 1
DIST-CO-RTE-PM: 06-MAD-99-R7.5/15.1
Work Description: WIDEN FREEWAY FROM 4 LANES TO 6 LANES.
Location Description: MADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR CA 91342
Resident Engineer: Eric Karlson Structure Rep.: Peter Moua
Sample Information
DIME Sample ID: 2021-03-03-9
TL Number from the TL Form: 039660
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 03/03/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/09/2021
The quantity of what the sample constitutes: 1 of 1 can
A brief description of the sample: Asphalt Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: San Joaquin Refining Co Inc
Material Information
Performance Grade: PG 70-10
Modified: No
Lot number: 9
Sublot number: 13
Tank number:
Time of sample:
HMA Supplier: Vulcan Materials
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade:
Multigrade Type:
Asphalt Binder Mix Number:
Test Results
Test 1 of 7
DIME Test ID: 2021-03-03-9-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 03/12/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Is mass change based on one or two containers?
|
Two
|
Any material loss from containers during heating process/testing?
|
No
|
Mass of empty container #1
|
174.160 grams
|
Mass of empty container #2
|
177.180 grams
|
Mass of container #1 before test (m1i)
|
209.290 grams
|
Mass of container #2 before test (m2i)
|
211.670 grams
|
Mass of container #1 after test (m1f)
|
209.290 grams
|
Mass of container #2 after test (m2f)
|
211.670 grams
|
Average mass change
|
0.000 percent
|
Test 2 of 7
DIME Test ID: 2021-03-03-9-2
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 03/12/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Std Specs
Test Result Compliance: complies
Additional Comments When Verified:
Is a normal test obtainable?
|
Yes
|
Number of replicates tested
|
One
|
Ductility of test #1 (D1)
|
140 cm
|
Ductility of sample
|
140 cm
|
Test 3 of 7
DIME Test ID: 2021-03-03-9-3
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/12/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Std Specs ORIG
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
Original binder
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
12.00 %
|
Stress Amplitude
|
0.138 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
89.5 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.153 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.15 kPa
|
Test 4 of 7
DIME Test ID: 2021-03-03-9-4
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/12/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Std Specs RTFO
Test Result Compliance: does not comply
Additional Comments When Verified:
Phase
|
RTFO residue
|
Test Plate Diameter
|
25 mm
|
Test Gap
|
1 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
10.00 %
|
Stress Amplitude
|
0.182 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
89.1 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
1.822 kPa
|
Test Temperature (Specimen 1)
|
70.0 C
|
Dynamic Shear, G*/sin(δ)
|
1.82 kPa
|
Test 5 of 7
DIME Test ID: 2021-03-03-9-5
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
This test has been superseded on 03/12/2021.
Reason: retested
Test 6 of 7
DIME Test ID: 2021-03-03-9-6
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Verified Date: 03/12/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Minimum test bath temperature at 240 s
|
0.0 C
|
Maximum test bath temperature at 240 s
|
0.0 C
|
Time of test load application
|
no data HH:MM:SS
|
File name of test data
|
no data
|
Time beam in bath
|
no data
|
Time test started
|
no data HH:MM:SS
|
Flags issued by software during test
|
no data
|
Correlation coefficient (R²)
|
0
|
Regression coefficient a
|
no data
|
Regression coefficient b
|
no data
|
Regression coefficient c
|
no data
|
Load at time 0.0
|
0.0 mN
|
Deflection at time 0.0 s
|
0.000 µm
|
Load at time 0.5 s
|
0.0 mN
|
Deflection at time 0.5 s
|
0.000 µm
|
Load at 60.0 s
|
0.0 mN
|
Beam deflection 60.0 s
|
0.000 µm
|
Measured Stiffness Modulus 60.0 s
|
218.000 mPa
|
Estimated Stiffness Modulus 60.0 s
|
217.000 mPa
|
Difference between stiffness moduli 60.0 s
|
no data
|
Estimated m-value 60.0 s
|
0.363
|
Test 7 of 7
DIME Test ID: 2021-03-03-9-7
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 03/12/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase
|
PAV residue
|
Test Plate Diameter
|
8 mm
|
Test Gap
|
2 mm
|
Test Frequency
|
10.0 rad/s
|
Strain Amplitude
|
1.00 %
|
Stress Amplitude
|
52.299 kPa
|
Phase Angle (δ) (for the 10 cycles)
|
61.1 degree
|
Complex Modulus (G*) (for the 10 measurements)
|
5229.882 kPa
|
Test Temperature (Specimen 1)
|
37.0 C
|
(G*) x sin(δ)=
|
4579 kPa
|