Print Report | Back to Sample Detail

Sample Record for 2021-03-02-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 208973 DEA: 120H1004 EFIS: 1200000180 COOP: 120670 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-405,73,405,605-9.3/24.3
Work Description: (Alternative Delivery) San Diego Freeway (I-405) Improvement Project SR-73 to I-605, Design Build Project, Administered by Orange County Transportation Authority, Caltrans METS to perform Source Inspection per RFP.
Location Description: Orange and Los Angeles Counties: 12-ORA-405 PM 9.3/24.2 / 07-LA-405 PM 0.0/1.2 12-ORA-22 PM R0.7/R3.8 / 12-ORA-22 PM R0.5/R0.7 12-ORA-73 PM R27.2/R27.8 / 12-ORA-605 PM 3.5/R1.6 07-LA-605 PM R0.0/R1.2
Contractor Name: OC 405 Partners
Contractor Address: 3100 W Lake Center Dr, Santa Ana, CA 92704
Resident Engineer: Hank Alonso (reports) Structure Rep.: Alex Angha (reports)

Sample Information

DIME Sample ID: 2021-03-02-2
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/02/2021
Date that the sample was received by the laboratory/organization performing the testing: 03/09/2021
The quantity of what the sample constitutes: 48 ea.
A brief description of the sample: ASTM F1554 Grade 55 All Thread Rod
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AM Nut and Bolt

Material Information

Rocap Number(s):
Heat Number(s): 58043509
Nut Mfg. Lot Number(s): DECT
Washer Mfg. Lot Number(s): 7638
Bolt Specification: F1554
Bolt Length(s): 55 1/2"
Nut Specification: A563
Washer Specification: F436
Finish: A153
Diameter/Size: 2 1/4"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 16

DIME Test ID: 2021-03-02-2-1
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 58043509/04
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size 2.250 in
Bolt Length 55.5 in
Gage Type Pass

Test 2 of 16

DIME Test ID: 2021-03-02-2-2
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Gage Type Pass

Test 3 of 16

DIME Test ID: 2021-03-02-2-3
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Gage Type Pass

Test 4 of 16

DIME Test ID: 2021-03-02-2-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Gage Type Pass

Test 5 of 16

DIME Test ID: 2021-03-02-2-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 58043509/04
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW PAINT
Size 2.250 in
Bolt Length 55.5 in
Measurement Average 7.09 mils

Test 6 of 16

DIME Test ID: 2021-03-02-2-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Bolt Length no data in
Measurement Average 8.24 mils

Test 7 of 16

DIME Test ID: 2021-03-02-2-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Bolt Length no data in
Measurement Average 9.3 mils

Test 8 of 16

DIME Test ID: 2021-03-02-2-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Bolt Length no data in
Measurement Average 9.91 mils

Test 9 of 16

DIME Test ID: 2021-03-02-2-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 7638
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 2.250 in
Bolt Length no data in
Measurement Average 8.26 mils

Test 10 of 16

DIME Test ID: 2021-03-02-2-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 7638
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 2.250 in
Bolt Length no data in
Measurement Average 6.47 mils

Test 11 of 16

DIME Test ID: 2021-03-02-2-11
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 32.37
Spacing Ok

Test 12 of 16

DIME Test ID: 2021-03-02-2-12
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number DECT
Finish Coating ASTM F2329 - Hot Dip
Product Markings 2H DH D/N
Size 2.250 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 31.7
Spacing Ok

Test 13 of 16

DIME Test ID: 2021-03-02-2-13
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 7638
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 2.250 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 37.55
Spacing Ok

Test 14 of 16

DIME Test ID: 2021-03-02-2-14
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/16/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 7638
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 2.250 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 37.55
Spacing Ok

Test 15 of 16

DIME Test ID: 2021-03-02-2-15
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/16/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1A58043509/040.4960.193643409010828.5fsaylor
UTM 67kip
Temperature 72 f

Test 16 of 16

DIME Test ID: 2021-03-02-2-16
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/16/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1B58043509/040.4980.195656139203427fsaylor
UTM 67kip
Temperature 72 f