Print Report | Back to Test Summary

Testing Report for 2021-03-04-2-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030H4004
EFIS: 0315000164
Project ID: 214686
QA Service Level: 1
DIST-CO-RTE-PM: 03-NEV,PLA,YOL-80-VAR
Work Description: REPLACE ELECTRICAL SIGNS & INSTALL FIBER OPTIC COMMUNICATION LINES.
Location Description: NEVADA, PLACER AND YOLO COUNTIES AT VARIOUS LOCATIONS
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Rakesh Chander
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-03-04-2
TL Number from the TL Form: na
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 3/4/2021
Date that the sample was received by the laboratory/organization performing the testing: 3/4/2021
The quantity of what the sample constitutes: 93
A brief description of the sample: 7/8 x 30" A449 Anchor Bolt hardware
From where was the sample collected: Fabricator
Laboratory sample identification: na
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): na
Heat Number(s): 201157
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: A449
Bolt Length(s): 30"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 7/8"
Bolt Mfg. Lot Number: 33122
Rocap Test Requirement(s): na
Lubricant Requirements(s): na

Test Information

DIME Test ID: 2021-03-04-2-8
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 3/10/2021
Verified Date: 3/11/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A449 Headed Bolt 10 Dea
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1 UNC 7/8 0.462 63371 281 137159 119840 55366 A449 Headed Bolt 10 Dea
UTM: 400kip
Temperature: 72