Print Report | Back to Test Summary

Testing Report for 2021-03-01-2-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 060Q9104
EFIS: 0614000005
Project ID: 215075
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-19.2/19.8
Work Description: BRIDGE DECK AND OUTSIDE GIRDER REPLACEMENT.
Location Description: TULARE COUNTY NEAR TIPTON FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF AVENUE 152 OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Javier Huerta
Structure Rep.: Peter Moua

Sample Information

DIME Sample ID: 2021-03-01-2
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 3/1/2021
Date that the sample was received by the laboratory/organization performing the testing: 3/4/2021
The quantity of what the sample constitutes: 4
A brief description of the sample: ASTM A706 Grade 60 Welded Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1202028162
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 3'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Information

DIME Test ID: 2021-03-01-2-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Date Tested: 3/5/2021
Verified Date: 3/8/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Mfg. Lot Number(s) Size Area (sqin) Peak Load (lbf) Peak Stress (psi) Comments Tested By
3 1 6/19mm 0.44 42181.14 95866 Ok Necking bewing
UTM: 400kip
Temperature: 72 f