Print Report | Back to Test Summary

Testing Report for 2021-03-05-3-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 0322222
EFIS:
Project ID: 99999
QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-03-05-3
TL Number from the TL Form:
Sample Submitted By Organization: Veleroo - Coolidge
Sample Organization Contact: 111-111-1111
Type of Sample: Quality Control
Type of Material: Asphalt Binder
Sample Taken Date: 3/5/2021
Date that the sample was received by the laboratory/organization performing the testing: 3/5/2021
The quantity of what the sample constitutes: 2 cans, split sample
A brief description of the sample: Asphalt Binder
From where was the sample collected: Manufacturer
Laboratory sample identification: 6416-100520
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: VSS Emultech

Material Information

Performance Grade: PG 64-16
Modified: No
Lot number:
Sublot number:
Tank number: 3
Time of sample: 8:00am
HMA Supplier:
Asphalt Binder Supplier: Pacific Northwest Oil - Stockton CA
Multigrade:
Multigrade Type:

Test Information

DIME Test ID: 2021-03-05-3-2
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Date Tested: 3/5/2021
Verified Date: 3/5/2021
Submitted By Organization: Veleroo - Coolidge
Organization Address: 123 Abc St,
Organization City: Coolidge
Organization State: AZ
Organization Zipcode: 88888
Organization Email:
Organization Phone: 111-111-1111
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Phase: Original binder
Test Plate Diameter: 25 mm
Phase Angle (δ) (for the 10 cycles): 49.3 degree
Dynamic Shear, G*/sin(δ): 1.36 kPa