Print Report | Back to Sample Detail

Sample Record for 2021-01-27-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214190 DEA: 024G41U4 EFIS: 0218000047 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS,SIS-5-Var
Work Description: REPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL.
Location Description: SHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING
Contractor Name: J.F. Shea Construction, Inc.
Contractor Address: 17400 Clear Creek Road, Redding, CA 96001
Resident Engineer: Nicole Mallory Structure Rep.: Adam Scardaci

Sample Information

DIME Sample ID: 2021-01-27-7
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 01/27/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/03/2021
The quantity of what the sample constitutes: 2
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 19657-1
Material/Compound/Elastomer ID: NA
Samples Representing: 1
Description (size): 3.45" x 14" x 24"
Comments:
Description (Number of Shims): 6
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2021-01-27-7-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 02/08/2021
Date Tested: 02/04/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 56
Reading #2 57
Reading #3 57
Reading #4 56
Reading #5 56
Mean 56.4

Test 2 of 4

DIME Test ID: 2021-01-27-7-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 02/08/2021
Date Tested: 02/04/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.077
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2352.4 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.077
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2374.22 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.073
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2432.76 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2374.2 lbf/in^2

Test 3 of 4

DIME Test ID: 2021-01-27-7-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 02/08/2021
Date Tested: 02/04/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.072
Sample 1 Tear Strength 253.8
Sample 2 Median Thickness 0.076
Sample 2 Tear Strength 239.8
Sample 3 Median Thickness 0.073
Sample 3 Tear Strength 247.1
Median of the Tear Strength Values 247.1 lb/in

Test 4 of 4

DIME Test ID: 2021-01-27-7-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 02/05/2021
Date Tested: 02/05/2021
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass