Print Report | Back to Test Summary

Testing Report for 2021-02-01-1-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 051F7904
EFIS: 0514000061
Project ID: 212571
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-56
Work Description: NOJOQUI CREEK BRIDGE (51-0018 L/R) RAILING UPGRADE
Location Description: IN SANTA BARBARA COUNTY NEAR BUELLTON AT NOJOQUI CREEK BRIDGE (BR #51-0018 L/R)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: David Ballentine
Structure Rep.: Andrew Rose

Sample Information

DIME Sample ID: 2021-02-01-1
TL Number from the TL Form:
Sample Submitted By Organization: Caltrans Vallejo Field Laboratory
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 2/1/2021
Date that the sample was received by the laboratory/organization performing the testing: 2/1/2021
The quantity of what the sample constitutes: 24
A brief description of the sample: HRC 555 End Anchors
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: PJ

Material Information

Production or Authorization Testing: Authorization Testing
Rebar Heat Number(s): 3500015159
Head Manufacturer Lot Number(s): 1
Rebar Size: #11
Headed Bar Model Name: HRC 555
Size of Head: Reduced Size - 4x
Head Connection Type:
Head Shape: Circular
Rebar Manufacturer: CMC Rebar Nucor
Head Manufacturer: nucor
Head Fabricator: Nucor and Gerdau
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2021-02-01-1-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 2/3/2021
Verified Date: 2/3/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Broke Head OFF
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
1 1 101467 101467 Broke Head OFF fsaylor
Temperature: 72 f
UTM: 400kip