Print Report | Back to Test Summary

Testing Report for 2021-01-04-8-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: ASCP
EFIS: ASCP
Project ID: 44444
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-01-04-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 1/4/2021
Date that the sample was received by the laboratory/organization performing the testing: 1/13/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: COC Sample
From where was the sample collected: Manufacturer
Laboratory sample identification: 21-002
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Holly Frontier Glendale

Material Information

Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample: 09:30
HMA Supplier:
Asphalt Binder Supplier:
Multigrade:
Multigrade Type:

Test Information

DIME Test ID: 2021-01-04-8-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Date Tested: 1/21/2021
Verified Date: 1/29/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: per 2018 standard specifications
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Is mass change based on one or two containers?: Two
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 166.871 grams
Mass of empty container #2: 175.683 grams
Mass of container #1 before test (m1i): 201.712 grams
Mass of container #2 before test (m2i): 211.279 grams
Mass of container #1 after test (m1f): 201.684 grams
Mass of container #2 after test (m2f): 211.246 grams
Average mass change: -0.087 percent