Print Report | Back to Test Summary

Testing Report for 2020-12-30-9-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030F2864
EFIS: 0320000123
Project ID: 214702
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99-7.92 / 8.4
Work Description: Remove and replace Consumnes River and Consumnes River Overflow bridge
Location Description: Sacramento County
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Masoud Saed
Structure Rep.: Chau Ha

Sample Information

DIME Sample ID: 2020-12-30-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 12/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 1/7/2021
The quantity of what the sample constitutes: 61
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire

Material Information

Comments:
Reel/Coil/Pack Number(s):
Number of Coils:
Group Number: 10961
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0569320-2, S0569120-2, S0569720-3, S0514120-2, S0525620, S0568320, S0218590, S0216056, S0218045, S0559420-2, S0514420-2, S0513920-2, S0514320-2
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden Wire

Test Information

DIME Test ID: 2020-12-30-9-6
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Date Tested: 1/7/2021
Verified Date: 1/12/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Heat Number Coil Area (sqin) Peak Load (lbf) Load at EUL (lbf) Chord Modulus (Msi) Elongation (in) Tested By
S0514120-2 S379465-6 0.214 60416 56621.3 28.9 1.91 bewing
UTM: 120kip
Temperature: 72 f
Extensometers: no data