Testing Report for 2020-12-03-5-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 65A0781
EFIS: 0017000212
Project ID: 208557
QA Service Level:
DIST-CO-RTE-PM: 03-YOL--
Work Description: Type 86H Concrete Bridge Rail
Location Description: Caltrans Dynamic Test Facility
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-12-03-5
TL Number from the TL Form: 225305
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/3/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/4/2020
The quantity of what the sample constitutes: 2 Cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nemetz Construction

Material Information

The concrete mix design number: Z1754120
The truck number from where the sample was collected: Truck 2
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2020-12-03-5-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 12/31/2020
Verified Date: 12/31/2020
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.96 in
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 27.9 in^2
Compressive strength (to nearest 10 psi): 5700 psi
Maximum load on cylinder 1: 158894 lbf
Maximum load on cylinder 2: 159883 lbf
Compressive strength of cylinder 1: 5676.0 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 5731.0 psi
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data