Print Report | Back to Sample Detail

Sample Record for 2020-12-04-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214466 DEA: 081F1414 EFIS: 0815000231 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-15-54.2/54.3
Work Description: Slab & lane replacement with JPCP & precast conc pavement, place HMA.
Location Description: Riverside and San Diego County
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Mike Bergevin Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-12-04-1
TL Number from the TL Form: 145758
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/04/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/07/2020
The quantity of what the sample constitutes: 4 Cylinders
A brief description of the sample: 4 Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1013-58
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA

Material Information

The concrete mix design number: 93-20-PCC-215
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: NA
The fabricator/manufacturer designation for the sample: NA
A detailed description of where the material sample was collected: NA
Where the material sample would have been placed if not sampled: UNKNOWN
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2020-12-04-1-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/28/2020
Date Tested: 12/11/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 2970 psi
Maximum load on cylinder 1 81690 lb
Maximum load on cylinder 2 86450 lb
Compressive strength of cylinder 1 2889.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3058.0 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data