Print Report | Back to Test Summary

Testing Report for 2020-11-13-9-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080F0304
EFIS: 0800020358
Project ID: 213764
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-60-R0.7/R3.0
Work Description: REMOVE AND REPLACE THREE OVERCROSSING BRIDGES ON ROUTE 60
Location Description: IN SAN BERNARDINO COUNTY IN AND NEAR CHINO AT VARIOUS LOCATIONS FROM O.1 MILE WEST OF PIPELINE AVENUE OVERCROSSING TO 0.1 MILE EAST OF BENSON AVENUE OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Joseph Lopez
Structure Rep.: Rodrigo Santa Cruz

Sample Information

DIME Sample ID: 2020-11-13-9
TL Number from the TL Form: 13
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/13/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/18/2020
The quantity of what the sample constitutes: 35 CY
A brief description of the sample: concrete cylinders
From where was the sample collected: Source
Laboratory sample identification: 1003-13
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1610836
The truck number from where the sample was collected: load 4
The batch plant ticket number from where the sample was collected: 10067295
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: monte vista ave bent cap intermediate and end diaphrams
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2020-11-13-9-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 11/27/2020
Verified Date: 12/28/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.99 in
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength (to nearest 10 psi): 4960 psi
Maximum load on cylinder 1: 142165 lb
Maximum load on cylinder 2: 137165 lb
Compressive strength of cylinder 1: 5044.9 psi
Type of fracture pattern of cylinder 1: 1
Compressive strength of cylinder 2: 4867.5 psi
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 14 days
Age of specimen in hours: no data