Print Report | Back to Test Summary

Testing Report for 2020-12-15-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 07301104
EFIS: 0714000009
Project ID: 214029
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60,710-710-R2.8/11.8, 24.1/25.1
Work Description: Roadway ex, place jointed plain concrete pavement & concrete barrieres
Location Description: In Los Angeles County at avocado Heights on Route 60 from 0.5 Mile west of Route 60/710 Separation to Route 60/605 Separation AND on Route 710 from 0.5 miles south of Route 710/60 Separation to 0.5 mile north of Route 710/60 Separation.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Sepand Minovi
Structure Rep.: Rick Jensen

Sample Information

DIME Sample ID: 2020-12-15-2
TL Number from the TL Form: NA
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/15/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/15/2020
The quantity of what the sample constitutes: 15
A brief description of the sample: Anchor Bolt Hardware
From where was the sample collected: Fabricator
Laboratory sample identification: NA
Structure unique identifier:
Structure name: na
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): na
Heat Number(s): 3600014793
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: F1554 Gr. 36
Bolt Length(s): 14"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 54220
Rocap Test Requirement(s): na
Lubricant Requirements(s): na

Test Information

DIME Test ID: 2020-12-15-2-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Date Tested: 12/23/2020
Verified Date: 12/24/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: F1554 Gr 36
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Size Area (in^2) Peak Load (lbf) Peak Load (kN) Tensile Strength (psi) Stress at Offset (psi) Load at Offset (lbf) Comments
1 UNC 3/4 0.334 24652 109 73688 50207 16769 F1554 Gr 36
UTM: 400kip
Temperature: 72