Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215374 DEA: 060X2704 EFIS: 0618000048
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-37.2/48.8
Work Description: PAVEMENT REHABILITATION
Location Description: FROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Unknown
DIME Sample ID: 2020-12-01-16
TL Number from the TL Form: C0X2704
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 12/01/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/15/2020
The quantity of what the sample constitutes: 1 Bag
A brief description of the sample: Soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200562
Structure unique identifier: 06-FRE-5-PM 37.2/48.8
Structure name:
The fabricator/manufacturer/facility name: Caltrans
The fabricator's/manufacturer's product name for the sample: 20-D-086
The fabricator/manufacturer designation for the sample: corrosion testing
A detailed description of where the material sample was collected: East Side of I-5 at PM 44.48, At Surface at Outlet
Where the material sample would have been placed if not sampled:
DIME Test ID: 2020-12-01-16-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 12/23/2020
Date Tested: 12/22/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5
|
383.00 Ohm-cm
|
Minimum soil resistivity at 15.5
|
383 Ohm-cm
|
Minimum soil resistance of the lab measurement
|
360 Ohms
|
Soil sample temperature
|
18 C
|
pH of soil
|
6.61
|
DIME Test ID: 2020-12-01-16-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/23/2020
Date Tested: 12/22/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type
|
Soils
|
Amount of the analyte in the sample
|
969
|
DIME Test ID: 2020-12-01-16-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/23/2020
Date Tested: 12/22/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type
|
Soils
|
Amount of the analyte in the sample
|
191
|