Print Report | Back to Test Summary

Testing Report for 2020-08-12-47-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 033H4504
EFIS: 0318000001
Project ID: 214899
QA Service Level: 1
DIST-CO-RTE-PM: 03-ED-50-33.8/34.2
Work Description: CONSTRUCT RW, WIDEN RDWY, COLD PLANE AC PVMT, & HMA OVERLAY.
Location Description: EL DORADO COUNTY AT FRESH POND FROM 0.6 TO 0.2 MILE WEST OF FOREST ROAD/OUTER LIMITS LANE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Jody Phillips
Structure Rep.: Dave Carlin

Sample Information

DIME Sample ID: 2020-08-12-47
TL Number from the TL Form: C788460
Sample Submitted By Organization: CT D03 - North Region Materials Lab
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 8/12/2020
Date that the sample was received by the laboratory/organization performing the testing: 8/13/2020
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 3/4 inch HMA - A
From where was the sample collected: Manufacturer
Laboratory sample identification: JMF20-034
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Aggresgates - Grantline Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:

Test Information

DIME Test ID: 2020-08-12-47-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Date Tested: 8/28/2020
Verified Date: 12/16/2020
Submitted By Organization: CT D03 - North Region Materials Lab
Organization Address: 5330 Arboga Rd,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-034. Test date estimated.
Test Result Compliance: complies
Additional Comments When Verified : JMF20-034

Submitted Test Results

Average Dry Tensile Strength: 193 psi
Average Wet Tensile Strength: 161 psi
Tensile Strength Ratio: 83