Print Report | Back to Test Summary

Testing Report for 2020-07-06-40-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 031G6504
EFIS: 0319000105
Project ID: 214801
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA,NEV-89-21.5/21.6,0.0/0.5
Work Description: COLD PLANE AC PAVEMENT AND PLACE HMA (TYPE A).
Location Description: PLACER AND NEVADA COUNTIES IN AND NEAR TRUCKEE FROM WEST RIVER STREET TO 0.2 MILE NORTH OF DEERFIELD DRIVE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Bojana Guiterrez
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-07-06-40
TL Number from the TL Form:
Sample Submitted By Organization: CT D03 - North Region Materials Lab
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 7/6/2020
Date that the sample was received by the laboratory/organization performing the testing: 7/7/2020
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 3/4 inch HMA - A w/RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: JMF20-031
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert - Martis Valley Plant

Material Information

RAP Source: Martis
Aggregate Size:
Aggregate Source:
RAP Stockpile: Static
Stockpile Size (tons):

Test Information

DIME Test ID: 2020-07-06-40-3
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Date Tested: 7/28/2020
Verified Date: 12/15/2020
Submitted By Organization: CT D03 - North Region Materials Lab
Organization Address: 5330 Arboga Rd,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-031
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Does this test use 1/4 sieve?: No
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 99 %
Cumulative percent passing the 3/8 in. sieve: 94 %
Cumulative percent passing the #4 sieve: 78 %
Cumulative percent passing the #8 sieve: 61 %
Cumulative percent passing the #16 sieve: 46 %
Cumulative percent passing the #30 sieve: 35 %
Cumulative percent passing the #50 sieve: 26 %
Cumulative percent passing the #100 sieve: 19 %
Cumulative percent passing the #200 sieve: 13.9 %