Print Report | Back to Sample Detail

Sample Record for 2015-04-03-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 7427 DEA: 07215934 EFIS: 0700001833 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-2.4/4.0
Work Description: Widen and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location Description: LOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
Contractor Name: FLATIRON WEST INC
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Mashhur Ali Structure Rep.: Steven Kim

Sample Information

DIME Sample ID: 2015-04-03-4
TL Number from the TL Form: 199546
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 04/03/2015
Date that the sample was received by the laboratory/organization performing the testing: 04/09/2015
The quantity of what the sample constitutes: 4
A brief description of the sample: Concrete Cylinders 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 856-46
Structure unique identifier: AVSF
Structure name: AVSF
The fabricator/manufacturer/facility name: site

Material Information

The concrete mix design number: S63061
The truck number from where the sample was collected: 368
The batch plant ticket number from where the sample was collected: na
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Austin Vault Sand Filter
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2015-04-03-4-1
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/01/2015
Date Tested: 05/01/2015
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4600 psi
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 28 days

Test 2 of 2

DIME Test ID: 2015-04-03-4-2
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/15/2015
Date Tested: 05/15/2015
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4990 psi
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Age of specimen 42 days