Testing Report for 2021-02-25-1-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214841 DEA: 034H1004 EFIS: 0318000176 QA Service Level: 1
DIST-CO-RTE-PM: 03-SIE-49-9.2/24.7
Work Description: INSTALL RETAINING STRUCTURE AND RSP CONCRETE EMBANKMENT.
Location Description: SIERRA COUNTY ON ROUTE 49 AT VARIOUS LOCATIONS
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Christopher Fallbeck Structure Rep.: Ross, Jimmer

Sample Information

DIME Sample ID: 2021-02-25-1
TL Number from the TL Form:
Sample Submitted By Organization: Caltrans Vallejo Field Laboratory
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 02/25/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/26/2021
The quantity of what the sample constitutes: 235
A brief description of the sample: Headed Rebar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Steel Group

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 3500016591
Head Manufacturer Lot Number(s): 3500016591
Rebar Size: #8
Headed Bar Model Name: HRC 555
Size of Head: Reduced Size - 4x
Head Connection Type: Forged
Head Shape: Circular
Rebar Manufacturer: Nucor
Head Manufacturer: Nucor
Head Fabricator: HRC
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2021-02-25-1-1
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/01/2021
Date Tested: 02/26/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Ok Necking
Additional Comments When Verified:

Submitted Test Results

Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
10.797878699729Ok Neckingfsaylor
Temperature 72 f
UTM 400kip