Sample Record for 2021-02-17-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214523 DEA: 07302504 EFIS: 0713000479 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-23-R3.3/R11.5
Work Description: PLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT.
Location Description: VENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Alan Davis Structure Rep.: Aziz Maghsoudloo

Sample Information

DIME Sample ID: 2021-02-17-9
TL Number from the TL Form: 1025-01
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/17/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/24/2021
The quantity of what the sample constitutes: 4
A brief description of the sample: CONCERETE CYLINDERS
From where was the sample collected: Job Site
Laboratory sample identification: 1025-01
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: security paving

Material Information

The concrete mix design number: 1610837
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: TRUCK MIXER
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2021-02-17-9-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 03/05/2021
Date Tested: 02/24/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 4550 psi
Maximum load on cylinder 1 123290 lb
Maximum load on cylinder 2 134740 lb
Compressive strength of cylinder 1 4332.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4766.2 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data

Test 2 of 2

DIME Test ID: 2021-02-17-9-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/02/2021
Date Tested: 03/17/2021
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 4
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.00 in
Average diameter of cylinder 3 6.00 in
Average diameter of cylinder 4 6.00 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.27 in^2
Cross sectional area of cylinder 3 28.27 in^2
Cross sectional area of cylinder 4 28.27 in^2
Compressive strength (to nearest 10 psi) 5170 psi
Maximum load on cylinder 1 123290 lb
Maximum load on cylinder 2 134740 lb
Maximum load on cylinder 3 165430 lb
Maximum load on cylinder 4 162020 lb
Compressive strength of cylinder 1 4332.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4766.2 psi
Compressive strength of cylinder 3 5851.8 psi
Compressive strength of cylinder 4 5731.2 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 4
Type of fracture pattern of cylinder 4 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Age of specimen 28 days
Age of specimen in hours no data