Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2021-02-01-13
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 02/01/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/01/2021
The quantity of what the sample constitutes: 1 sample
A brief description of the sample: Portland Cement
From where was the sample collected: Manufacturer
Laboratory sample identification: CM218220
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL Portland 220
DIME Test ID: 2021-02-01-13-1
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/18/2021
Date Tested: 02/12/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 day test @1400
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
3 days
|
The amount of flow
|
104 %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
4388 psi
|
Compressive strength of 2nd specimen
|
4464 psi
|
Compressive strength of 3rd specimen
|
4172 psi
|
Average Compressive strength (to nearest 10 psi)
|
4340 psi
|
DIME Test ID: 2021-02-01-13-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/18/2021
Date Tested: 02/16/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day test @ 1400
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
11 days
|
The amount of flow
|
104 %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
5262 psi
|
Compressive strength of 2nd specimen
|
5204 psi
|
Compressive strength of 3rd specimen
|
5359 psi
|
Average Compressive strength (to nearest 10 psi)
|
5280 psi
|
DIME Test ID: 2021-02-01-13-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/18/2021
Date Tested: 03/09/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test @ 1430
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
26 days
|
The amount of flow
|
104.00 %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
5843 psi
|
Compressive strength of 2nd specimen
|
no data
|
Compressive strength of 3rd specimen
|
no data
|
Average Compressive strength (to nearest 10 psi)
|
no data
|
DIME Test ID: 2021-02-01-13-4
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 03/18/2021
Date Tested: 02/18/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
112 seconds
|
Fineness
|
4275 cm^2/g
|
DIME Test ID: 2021-02-01-13-5
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Verified Date: 03/18/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 14 day measure
Test Result Compliance:
Additional Comments When Verified:
Specimen A Initial measurement at 24 hours
|
0.2918 in
|
Specimen B Initial measurement at 24 hours
|
0.2699 in
|
Specimen C Initial measurement at 24 hours
|
0.2586 in
|
Specimen D Initial measurement at 24 hours
|
0.2787 in
|
Specimen A Final measurement at 14 days
|
0.2923 in
|
Specimen B Final measurement at 14 days
|
0.2704 in
|
Specimen C Final measurement at 14 days
|
0.259 in
|
Specimen D Final measurement at 14 days
|
0.2792 in
|
The average length of change of the four specimens
|
0.005 %
|
DIME Test ID: 2021-02-01-13-6
Test Method: ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement
Verified Date: 03/18/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial length of specimen
|
0.2862
|
Final length of specimen
|
0.2934
|
Change in length of specimen(In percent)
|
0.07 %
|
Gauge Length
|
10
|
DIME Test ID: 2021-02-01-13-7
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 03/18/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.15
|
Water Content
|
248
|
The amount of flow (In percent)
|
92 %
|
The amount of water used (In percent)
|
70.86 %
|
Net Weight of Sample
|
825.4 grams
|
Air Content
|
8 %
|
DIME Test ID: 2021-02-01-13-8
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 03/18/2021
Date Tested: 03/10/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mass of Water
|
186 g
|
Mass of Dry Cement
|
650 g
|
Water required for normal consistency
|
29.0 %
|
DIME Test ID: 2021-02-01-13-9
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 03/18/2021
Date Tested: 03/10/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type IV grade reagent water
|
Initial time of setting
|
167 min
|
Final time of setting
|
322 min
|
DIME Test ID: 2021-02-01-13-10
Test Method: ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
Verified Date: 03/18/2021
Date Tested: 03/10/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial time of setting
|
217 min
|
Final time of setting
|
347 min
|