Print Report | Back to Sample Detail

Sample Record for 2021-02-01-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-02-01-12
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 02/01/2021
Date that the sample was received by the laboratory/organization performing the testing: 02/01/2021
The quantity of what the sample constitutes: 1 sample
A brief description of the sample: Portland Cement
From where was the sample collected: Manufacturer
Laboratory sample identification: CM218219
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL Portland 219

Material Information

Brand: CCRL
Mill: CCRL
Type of Cementitious Material: Type II Cement

Test Results

Test 1 of 11

DIME Test ID: 2021-02-01-12-1
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/18/2021
Date Tested: 02/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Age of specimen 3 days
The amount of flow 105 %
The amount of water used 48.5 %
Compressive strength of 1st specimen 3394 psi
Compressive strength of 2nd specimen 3481 psi
Compressive strength of 3rd specimen 3347 psi
Average Compressive strength (to nearest 10 psi) 3410 psi

Test 2 of 11

DIME Test ID: 2021-02-01-12-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/18/2021
Date Tested: 02/15/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day break @ 1400
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Age of specimen 7 days
The amount of flow 105 %
The amount of water used 48.4 %
Compressive strength of 1st specimen 4033 psi
Compressive strength of 2nd specimen 4197 psi
Compressive strength of 3rd specimen 4387 psi
Average Compressive strength (to nearest 10 psi) 4210 psi

Test 3 of 11

DIME Test ID: 2021-02-01-12-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/18/2021
Date Tested: 03/08/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? no
Age of specimen 28 days
The amount of flow 105 %
The amount of water used 48.4 %
Compressive strength of 1st specimen 5131 psi
Compressive strength of 2nd specimen 4920 psi
Compressive strength of 3rd specimen 5126 psi
Average Compressive strength (to nearest 10 psi) 5060 psi

Test 4 of 11

DIME Test ID: 2021-02-01-12-4
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 03/18/2021
Date Tested: 02/18/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used Test Method A
Test Time 92 seconds
Fineness 3866 cm^2/g

Test 5 of 11

DIME Test ID: 2021-02-01-12-5
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Verified Date: 03/18/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 14 day measure
Test Result Compliance:
Additional Comments When Verified:
Specimen A Initial measurement at 24 hours 0.2563 in
Specimen B Initial measurement at 24 hours 0.315 in
Specimen C Initial measurement at 24 hours 0.258 in
Specimen D Initial measurement at 24 hours 0.2549 in
Specimen A Final measurement at 14 days 0.2567 in
Specimen B Final measurement at 14 days 0.3155 in
Specimen C Final measurement at 14 days 0.2585 in
Specimen D Final measurement at 14 days 0.2551 in
The average length of change of the four specimens 0.004 %

Test 6 of 11

DIME Test ID: 2021-02-01-12-6
Test Method: ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement
Verified Date: 03/18/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial length of specimen 0.2604
Final length of specimen 0.2652
Change in length of specimen(In percent) 0.05 %
Gauge Length 10

Test 7 of 11

DIME Test ID: 2021-02-01-12-7
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 03/18/2021
Date Tested: 03/11/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity 3.15
Water Content 248
The amount of flow (In percent) 94 %
The amount of water used (In percent) 70.86 %
Net Weight of Sample 823.3 grams
Air Content 8 %

Test 8 of 11

DIME Test ID: 2021-02-01-12-8
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 03/18/2021
Date Tested: 03/10/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mass of Water 180 g
Mass of Dry Cement 650 g
Water required for normal consistency 28.0 %

Test 9 of 11

DIME Test ID: 2021-02-01-12-9
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 03/18/2021
Date Tested: 03/10/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used Type IV grade reagent water
Initial time of setting 136 min
Final time of setting 341 min

Test 10 of 11

DIME Test ID: 2021-02-01-12-10
Test Method: ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
Verified Date: 03/18/2021
Date Tested: 03/10/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial time of setting 194 min
Final time of setting 371 min

Test 11 of 11

DIME Test ID: 2021-02-01-12-11
Test Method: ASTM C451-13: Standard Test Method for Early Stiffening of Hydraulic Cement (Paste Method)
Verified Date: 03/18/2021
Date Tested: 03/12/2021
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 144 ml water used
Test Result Compliance:
Additional Comments When Verified:
Percent final penetration 48 %