Print Report | Back to Sample Detail

Sample Record for 2021-01-28-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-01-28-4
TL Number from the TL Form:
Sample Submitted By Organization: Granite Construction Company - Coastal
Sample Organization Contact: (408) 327-7023
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2021
The quantity of what the sample constitutes: JMF Renewal
A brief description of the sample: 1/2 HMA Type A
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Felton

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2021-01-28-4-1
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 01/28/2021
Date Tested: 02/08/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids 3.8 %
Percent Air Voids 2 4.3 %
Percent Air Voids 3 4.0 %
Percent Air Voids Average 4.0 %

Test 2 of 7

DIME Test ID: 2021-01-28-4-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/28/2021
Date Tested: 03/12/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.35 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 3 of 7

DIME Test ID: 2021-01-28-4-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 01/28/2021
Date Tested: 02/08/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.347
Bulk Specific Gravity 2 2.336
Bulk Specific Gravity 3 2.342
Average Bulk Specific Gravity 2.342

Test 4 of 7

DIME Test ID: 2021-01-28-4-4
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/28/2021
Date Tested: 02/11/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.440
Theoretical maximum density at 25°C (77°F) no data

Test 5 of 7

DIME Test ID: 2021-01-28-4-5
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
This test has been superseded on 01/29/2021.
Reason: retested

Test 6 of 7

DIME Test ID: 2021-01-28-4-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 01/29/2021
Date Tested: 03/26/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 149 psi
Average Wet Tensile Strength 123 psi
Tensile Strength Ratio 0.82

Test 7 of 7

DIME Test ID: 2021-01-28-4-7
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 01/29/2021
Date Tested: 03/26/2019
Submitted By Organization: Granite Construction Company - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A) 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B) 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A) -3.85 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B) -4.47 mm
Stripping Inflection Point (Wheel A) 13897
Stripping Inflection Point (Wheel B) 15405