Print Report | Back to Test Summary

Testing Report for 2021-01-28-4-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2021-01-28-4
TL Number from the TL Form:
Sample Submitted By Organization: Granite Construction - Coastal
Sample Organization Contact: (408) 327-7023
Type of Sample: Quality Control
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/28/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2021
The quantity of what the sample constitutes: JMF Renewal
A brief description of the sample: 1/2 HMA Type A
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Felton

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:

Test Information

DIME Test ID: 2021-01-28-4-1
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 01/28/2021
Date Tested: 02/08/2019
Submitted By Organization: Granite Construction - Coastal
Organization Address: 715 Comstock Street,
Organization City: Santa Clara
Organization State: CA
Organization Zipcode: 95054
Organization Email: ryan.gibbs@gcinc.com
Organization Phone: (408) 327-7023
General Comments for this Test:
Additional Comments When Verified :

Submitted Test Results

Average Dry Tensile Strength 149 psi
Average Wet Tensile Strength 123 psi
Tensile Strength Ratio 0.82