Print Report | Back to Test Summary

Testing Report for 2021-01-11-11-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209520 DEA: 06470904 EFIS: 0600000973 COOP: 061529 QA Service Level: 1
DIST-CO-RTE-PM: 06-MAD-99-R7.5/15.1
Work Description: WIDEN FREEWAY FROM 4 LANES TO 6 LANES.
Location Description: MADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Eric Karlson Structure Rep.: Moua, Peter

Sample Information

DIME Sample ID: 2021-01-11-11
TL Number from the TL Form: C039626
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 01/11/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/22/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Project Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: VULCAN MATERIALS MADERA

Material Information

Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier:
Multigrade:
Multigrade Type:

Test Information

DIME Test ID: 2021-01-11-11-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 01/29/2021
Date Tested: 01/26/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Additional Comments When Verified :

Submitted Test Results

Phase Original binder
Test Plate Diameter 25 mm
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.144 kPa
Phase Angle (δ) (for the 10 cycles) 89.5 degree
Complex Modulus (G*) (for the 10 measurements) 1.199 kPa
Test Temperature 70.0 C
Dynamic Shear, G*/sin(δ) 1.20 kPa