Print Report | Back to Test Summary

Testing Report for 2020-12-15-20-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215023 DEA: 060U4704 EFIS: 0615000301 QA Service Level: 1
DIST-CO-RTE-PM: 06-KER,KIN-5-81.7/87.0,0.0/0.3
Work Description: CONSTRUCT CRCP, JPCP AND INSTALL TRAFFIC MONITORING STATIONS.
Location Description: KERN AND KINGS COUNTIES NEAR KETTELMAN CITY FROM 0.6 MILE SOUTH OF TWISSELMAN ROAD OVERCROSSING TO 0.3 MILE NORTH OF KERN/KINGS COUNTY LINE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Din Dadawalla Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-12-15-20
TL Number from the TL Form: C040288
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 12/15/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/22/2021
The quantity of what the sample constitutes: 1 of 1
A brief description of the sample: Project Sample
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPM AVENAL

Material Information

Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier:
Multigrade:
Multigrade Type:

Test Information

DIME Test ID: 2020-12-15-20-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 01/27/2021
Date Tested: 01/25/2021
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Additional Comments When Verified :

Submitted Test Results

Is a normal test obtainable? Yes
Number of replicates tested Three
Ductility of test #1 (D1) 110 cm
Ductility of test #2 (D2) 150 cm
Ductility of test #3 (D3) 150 cm
Ductility of sample 137 cm