Print Report | Back to Test Summary

Testing Report for 2021-01-12-1-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214029 DEA: 07301104 EFIS: 0714000009 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-60,710-710-R2.8/11.8, 24.1/25.1
Work Description: Roadway ex, place jointed plain concrete pavement & concrete barrieres
Location Description: In Los Angeles County at avocado Heights on Route 60 from 0.5 Mile west of Route 60/710 Separation to Route 60/605 Separation AND on Route 710 from 0.5 miles south of Route 710/60 Separation to 0.5 mile north of Route 710/60 Separation.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Sepand Minovi Structure Rep.: Win, Thein

Sample Information

DIME Sample ID: 2021-01-12-1
TL Number from the TL Form: NA
Sample Submitted By Organization: CT QASI - Bay Area Field Laboratory
Sample Organization Contact: (707) 649-5453
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/12/2021
Date that the sample was received by the laboratory/organization performing the testing: 01/14/2021
The quantity of what the sample constitutes: 960
A brief description of the sample: Anchor Bolts 2 1/2"
From where was the sample collected: Fabricator
Laboratory sample identification: NA
Structure unique identifier:
Structure name: NA
The fabricator/manufacturer/facility name: Universal Industrial Sales Inc

Material Information

Rocap Number(s): NA
Heat Number(s): 1202024451
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: F1554-55
Bolt Length(s): 5'-0"
Nut Specification: NA
Washer Specification: NA
Finish: HDG
Diameter/Size: 2.5"
Bolt Mfg. Lot Number: NA
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA

Test Information

DIME Test ID: 2021-01-12-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/25/2021
Date Tested: 01/21/2021
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified :

Submitted Test Results

Sample No. 1C
Rocap Number no data
Heat Number(s) 1202024451
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings YELLOW
Size 2.5 in
Bolt Length 60 in
Gage Type Pass