Print Report | Back to Sample Detail

Sample Record for 2020-12-01-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215374 DEA: 060X2704 EFIS: 0618000048 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-37.2/48.8
Work Description: PAVEMENT REHABILITATION
Location Description: FROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 2716 Granite Court, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-12-01-17
TL Number from the TL Form: C0X2706
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 12/01/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/15/2020
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: Soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200563
Structure unique identifier: 06-FRE-05-PM 37.2/48.8
Structure name:
The fabricator/manufacturer/facility name: Caltrans

Material Information

The fabricator's/manufacturer's product name for the sample: 20-D-088
The fabricator/manufacturer designation for the sample: Corrosion testing
A detailed description of where the material sample was collected: East Side of I-5 at PM 47.58, at surface at Outlet
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 3

DIME Test ID: 2020-12-01-17-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 12/23/2020
Date Tested: 12/22/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5 492.00 Ohm-cm
Minimum soil resistivity at 15.5 492 Ohm-cm
Minimum soil resistance of the lab measurement 465 Ohms
Soil sample temperature 17.8 C
pH of soil 6.78

Test 2 of 3

DIME Test ID: 2020-12-01-17-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/23/2020
Date Tested: 12/22/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 1440

Test 3 of 3

DIME Test ID: 2020-12-01-17-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/23/2020
Date Tested: 12/22/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type Soils
Amount of the analyte in the sample 122