Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215364 DEA: 07333204 EFIS: 0716000301
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-.8/.8
Work Description: INSTALL SOLAR PV POWERED LIGHTING SYSTEM.
Location Description: IN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA.
Contractor Name: GENUINE ENGINEERING INC
Contractor Address: 11762 De Palma Road,Suite 1C, PMB 225, Corona, CA 92883
Resident Engineer: Mohammad Khan Structure Rep.: Chanh Tong
DIME Sample ID: 2020-11-30-16
TL Number from the TL Form: C002434
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 11/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 12/04/2020
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: soil
From where was the sample collected: Job Site
Laboratory sample identification: CR20200558
Structure unique identifier: 06-KER-005 1.12 PM
Structure name: Solar Panel Project
The fabricator/manufacturer/facility name: Caltrans
The fabricator's/manufacturer's product name for the sample: HA-20-002
The fabricator/manufacturer designation for the sample: Corrosion testing
A detailed description of where the material sample was collected: 0-2 feet depth
Where the material sample would have been placed if not sampled:
DIME Test ID: 2020-11-30-16-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 12/22/2020
Date Tested: 12/16/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5
|
2030.00 Ohm-cm
|
Minimum soil resistivity at 15.5
|
2030 Ohm-cm
|
Minimum soil resistance of the lab measurement
|
1850 Ohms
|
Soil sample temperature
|
19.4 C
|
pH of soil
|
7.44
|
DIME Test ID: 2020-11-30-16-2
Test Method: CTM 417-June 2014: Method of Testing Soils and Waters for Sulfate Content
Verified Date: 12/22/2020
Date Tested: 12/16/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type
|
Soils
|
Amount of the analyte in the sample
|
168
|
DIME Test ID: 2020-11-30-16-3
Test Method: CTM 422-June 2014: Method of Testing Soils and Waters for Chloride Content
Verified Date: 12/22/2020
Date Tested: 12/16/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Material type
|
Soils
|
Amount of the analyte in the sample
|
29
|