Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215317 DEA: 101J0104 EFIS: 1018000079
QA Service Level: 1
DIST-CO-RTE-PM: 10-CAL,CAL-88,34-34.6/2.2
Work Description: Construct fuel island canopies.
Location Description: In Calaveras and Alpine counties on Route 26 at the West Point Maintenance Station and on Route 88 at the Caples Lake Maintenance Station.
Contractor Name: CAL ELECTRO, INC. - Valerie Jenkins
Contractor Address: 3710 Electro Way, Redding, CA 96002
Resident Engineer: Pawan Garg Structure Rep.: Brandon Thurber
DIME Sample ID: 2020-10-16-11
TL Number from the TL Form: C529044
Sample Submitted By Organization: Wood
Sample Organization Contact: (916) 396-3815
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 10/16/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/18/2020
The quantity of what the sample constitutes: bag
A brief description of the sample: top soil for corrosion testing
From where was the sample collected: Job Site
Laboratory sample identification: CR20200503
Structure unique identifier: 10-ALP-88-0/0
Structure name: Woodfords MS
The fabricator/manufacturer/facility name: Caltrans
The fabricator's/manufacturer's product name for the sample: Top Soil sample
The fabricator/manufacturer designation for the sample: corrosion
A detailed description of where the material sample was collected: 1-5 feet depth
Where the material sample would have been placed if not sampled:
DIME Test ID: 2020-10-16-11-1
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Verified Date: 11/24/2020
Date Tested: 11/20/2020
Submitted By Organization: Wood
Organization Address: 9177 Sky Park Court,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92123
Organization Email: stephanie.antonucci@woodplc.com
Organization Phone: (916) 396-3815
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Minimum soil resistance corrected to 15.5
|
5051.00 Ohm-cm
|
Minimum soil resistivity at 15.5
|
5051 Ohm-cm
|
Minimum soil resistance of the lab measurement
|
4500 Ohms
|
Soil sample temperature
|
20.4 C
|
pH of soil
|
6.25
|