Print Report | Back to Test Summary

Testing Report for 2014-02-14-13454655-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 10016 DEA: 06342524 EFIS: 0600000381 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-180-R71.8/74.5
Work Description: NEW EXPRESS HIGHWAY
Location Description: FRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mark Mengoni Structure Rep.: Bloom, Mike

Sample Information

DIME Sample ID: 2014-02-14-13454655
TL Number from the TL Form:
Sample Submitted By Organization: Trinity Engineering Laboratories, Inc. - Fresno
Sample Organization Contact: 559-292-2188
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 02/14/2014
Date that the sample was received by the laboratory/organization performing the testing: 02/15/2014
The quantity of what the sample constitutes: 8 cylinders
A brief description of the sample: Type II Cement
From where was the sample collected: Other
Laboratory sample identification: 2014-02-14-006
Structure unique identifier: Hwy 180 at Fowler Switch Canal
Structure name: Hwy 180 at Fowler Switch Canal
The fabricator/manufacturer/facility name: Hwy 180 Mainling Bridge Deck

Material Information

The concrete mix design number: ND14505
The truck number from where the sample was collected: 9474
The batch plant ticket number from where the sample was collected: 114104647
Concrete batch plant: 114
The fabricator/manufacturer designation for the sample: Plant
A detailed description of where the material sample was collected: Hwy 180 at Fowler Switch Canal
Where the material sample would have been placed if not sampled: Hwt 180 at Fowler Switch Canal
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2014-02-14-13454655-1
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 04/02/2014
Date Tested: 02/14/2014
Submitted By Organization: Trinity Engineering Laboratories, Inc. - Fresno
Organization Address: 2437 N. Sunnyside Ave.,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93727
Organization Email:
Organization Phone: 559-292-2188
General Comments for this Test:
Additional Comments When Verified :

Submitted Test Results

Unit system used? US Units
Number of specimens 2
Test performed With density determined by dimension measurements
Average cylinder density (to nearest 1 pcf) 148.6 lb/ft^3
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters) no data