Print Report | Back to Test Summary

Testing Report for 2020-10-22-2-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 77777 DEA: STOCK-CHEM EFIS: STOCK-CHEM QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-22-2
TL Number from the TL Form:
Sample Submitted By Organization: Caltrans Vallejo Field Laboratory
Sample Organization Contact: (510) 774-6009
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 10/22/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/23/2020
The quantity of what the sample constitutes: 117 Lft
A brief description of the sample: 3/8" x 48" Neoprene bearing pad
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cal Neva Supply

Material Information

Mfg. Lot Number(s): 020620
Material/Compound/Elastomer ID: 0012270880
Samples Representing: 117 Lft
Description (size): .375X48"
Comments:
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): 020620
Batch Number: 8168

Test Information

DIME Test ID: 2020-10-22-2-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 10/29/2020
Date Tested: 10/26/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:

Submitted Test Results

Number of specimens tested 3
UTM 2kip
Humidity 50.00 %
Temperature 72 F
Sample 1 Median Thickness 0.08
Sample 1 Tear Strength 249.2
Sample 2 Median Thickness 0.08
Sample 2 Tear Strength 229.6
Sample 3 Median Thickness 0.081
Sample 3 Tear Strength 243.6
Median of the Tear Strength Values 243.6 lb/in