Print Report | Back to Sample Detail

Sample Record for 2013-07-24-8818

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-4.7/5.6
Work Description: REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location Description: SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Tom Davis Structure Rep.: Anh Ma

Sample Information

DIME Sample ID: 2013-07-24-8818
TL Number from the TL Form:
Sample Submitted By Organization: Signet Testing Laboratories - Anaheim
Sample Organization Contact: (714) 399-1500
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/24/2013
Date that the sample was received by the laboratory/organization performing the testing: 07/24/2013
The quantity of what the sample constitutes: 4 cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification: 2013-07-24-08-45-8351
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan

Material Information

The concrete mix design number: 103612F
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 145088
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Footing
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 18

DIME Test ID: 2013-07-24-8818-1
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 10/23/2013
Date Tested: 10/16/2013
Submitted By Organization: Signet Testing Laboratories - Anaheim
Organization Address: 1320 Simpson Circle,
Organization City: Anaheim
Organization State: CA
Organization Zipcode: 92806
Organization Email:
Organization Phone: (714) 399-1500
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample set2
Volume of the measure 0.25 ft^3
Density of concrete 146.1 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content 1.7 %

Test 2 of 18

DIME Test ID: 2013-07-24-8818-2
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/23/2013
Date Tested: 10/16/2013
Submitted By Organization: Signet Testing Laboratories - Anaheim
Organization Address: 1320 Simpson Circle,
Organization City: Anaheim
Organization State: CA
Organization Zipcode: 92806
Organization Email:
Organization Phone: (714) 399-1500
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4 inch

Test 3 of 18

DIME Test ID: 2013-07-24-8818-3
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/23/2013
Date Tested: 10/16/2013
Submitted By Organization: Signet Testing Laboratories - Anaheim
Organization Address: 1320 Simpson Circle,
Organization City: Anaheim
Organization State: CA
Organization Zipcode: 92806
Organization Email:
Organization Phone: (714) 399-1500
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 81.6 F

Test 4 of 18

DIME Test ID: 2013-07-24-8818-4
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample Station 10 90 wall 316R
Volume of the measure 0.25 ft^3
Density of concrete 146.1 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content 1.7 %

Test 5 of 18

DIME Test ID: 2013-07-24-8818-5
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4 inch

Test 6 of 18

DIME Test ID: 2013-07-24-8818-6
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 81.6 F

Test 7 of 18

DIME Test ID: 2013-07-24-8818-7
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/06/2013
Date Tested: 07/31/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens no data
Cylinder Age 7 days
Break Description of Cylinder 1 (if not 'cone') no data

Test 8 of 18

DIME Test ID: 2013-07-24-8818-8
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/06/2013
Date Tested: 09/18/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens no data
Cylinder Age 56 days
Break Description of Cylinder 1 (if not 'cone') no data

Test 9 of 18

DIME Test ID: 2013-07-24-8818-10
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/06/2013
Date Tested: 11/06/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens no data
Cylinder Age 7 days
Break Description of Cylinder 1 (if not 'cone') no data

Test 10 of 18

DIME Test ID: 2013-07-24-8818-11
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample station 10 90 wall 316R
Volume of the measure 0.25 ft^3
Density of concrete 146.1 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data

Test 11 of 18

DIME Test ID: 2013-07-24-8818-12
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4 inch

Test 12 of 18

DIME Test ID: 2013-07-24-8818-13
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 81.6 F

Test 13 of 18

DIME Test ID: 2013-07-24-8818-14
Test Method: ASTM C138-10b: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample station 10 90 wall 316R
Volume of the measure 0.25 ft^3
Density of concrete 146.1 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data

Test 14 of 18

DIME Test ID: 2013-07-24-8818-15
Test Method: ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 4 inch

Test 15 of 18

DIME Test ID: 2013-07-24-8818-16
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 11/06/2013
Date Tested: 07/24/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 81.6 F

Test 16 of 18

DIME Test ID: 2013-07-24-8818-17
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/06/2013
Date Tested: 07/31/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens no data
Cylinder Age 7 days
Break Description of Cylinder 1 (if not 'cone') no data

Test 17 of 18

DIME Test ID: 2013-07-24-8818-18
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/06/2013
Date Tested: 09/18/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens no data
Cylinder Age 56 days
Break Description of Cylinder 1 (if not 'cone') no data

Test 18 of 18

DIME Test ID: 2013-07-24-8818-19
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 11/06/2013
Date Tested: 08/21/2013
Submitted By Organization: Vulcan Materials Company - San Diego
Organization Address: 10051 Black Mountain Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92126
Organization Email: picenor@vmcmail.com
Organization Phone: 6195729564
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed no data
Comment on any defect in either specimen or caps (Max 250 Characters) no data