Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-09-25-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 09/25/2019
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 1
A brief description of the sample: 3/4inch HMA-SP RAP WMA PG 64-16
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Syar industry
Source Identification (SMARA, name of Pit or Job Site): 91-48-0002::LAKE HERMAN QUARRY
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2019-09-25-10-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-335 Coarse Agg. One Fractured face
Test Result Compliance:
Additional Comments When Verified:
Method
|
2 - Individual Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 1 Faced
|
Weighted average percentage of fractured, coarse, 1 faced particles
|
99 %
|
DIME Test ID: 2019-09-25-10-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-335 Coarse Agg. Two Fractured face
Test Result Compliance:
Additional Comments When Verified:
Method
|
2 - Individual Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 2 Faced
|
Weighted average percentage of fractured, coarse, 2 faced particles
|
99 %
|
DIME Test ID: 2019-09-25-10-3
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-335 Fine Agg. One Fractured face
Test Result Compliance:
Additional Comments When Verified:
Method
|
2 - Individual Fracture Determination
|
Aggregate Size and Fracture Type
|
Fine 1 Faced
|
Percentage of fractured, fine, 1 faced particles tested
|
100 %
|
DIME Test ID: 2019-09-25-10-4
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-96 Los Angles rattler
Test Result Compliance:
Additional Comments When Verified:
Grading designation
|
C
|
Percent loss after 100 revolutions
|
3 %
|
Percent loss after 500 revolutions
|
14 %
|
DIME Test ID: 2019-09-25-10-5
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-176 Sand Equivalent
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2019-09-25-10-6
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-Fine aggregate angularity %
Test Result Compliance:
Additional Comments When Verified:
What test method is performed?
|
Method A
|
Bulk dry specific gravity
|
2.657
|
Average uncompacted voids
|
47 %
|
DIME Test ID: 2019-09-25-10-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample ASTM D 4791 Flat and Elongated particles (% by mass at 5:1)
Test Result Compliance:
Additional Comments When Verified:
Method
|
B
|
Determination
|
By Mass
|
Dimensional ratio used
|
1:5
|
Weighted percentage of particles (by mass) that were flat and elongated
|
0.0 %
|
Weighted percentage of particles (by mass) that were not flat and elongated
|
100 %
|
DIME Test ID: 2019-09-25-10-8
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-85 Bulk Specific gravity of Coarse aggregate
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing
|
Bulk
|
Specific Gravity
|
2.657
|
Absorption
|
2.7 %
|
DIME Test ID: 2019-09-25-10-9
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 10/16/2019
Date Tested: 09/25/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Aggregate Quality sample T-84 Bulk Specific gravity of Fine aggregate
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity
|
2.591
|
Bulk specific gravity (SSD Basis)
|
2.729
|
Apparent specific gravity
|
2.883
|
Absorption
|
3.9 %
|